Complete alternators
Power-generation alternators matched to engine output, voltage and frequency.
- Stamford and equivalent alternators
- Mecc Alte, Stamford (Newage) and Leroy-Somer
- Standby, prime and continuous duty
Generator alternators and alternator components for replacement, repair and upgrades.

Overview
The alternator turns the engine’s power into electricity, and the quality of that electricity, steady voltage and frequency, depends on it. Powermec’s Perkins-powered generator sets are built with Mecc Alte, Stamford (Newage) or Leroy-Somer alternators.
We supply brushless, AVR-controlled power-generation alternators for standby, prime and continuous duty, together with the components to repair them. Our technicians test before anything is replaced, so you pay for the fault, not for guesswork.
Genuine Perkins alternators
12 V and 24 V Perkins charging alternators for generator-set, industrial, agricultural and construction engines. Select an alternator to see it in detail; our parts team confirms the exact match from your engine serial number.
For engines on a 12 V electrical system, keeping the starting battery charged and powering the engine’s controls.
Typical applications
A higher-output, belt-driven alternator for 12 V engines that also run additional electrical equipment.
Typical applications
For engines on a 24 V system, where larger starter motors and longer duty cycles call for a heavier-duty unit.
Typical applications
A compact 24 V unit for installations where space around the engine is limited.
Typical applications
How an alternator works
A brushless alternator has five working parts. A fault in any one of them shows up as no voltage, low voltage or unstable voltage.
The engine turns the main rotor at a fixed speed, 1,500 rpm for 50 Hz on a four-pole machine.
A small generator on the same shaft produces the current that magnetises the main rotor.
Diodes on the shaft turn the exciter’s AC into DC for the rotor. One failed diode can cause low or unstable voltage.
The rotor’s magnetic field induces the output voltage in the stator windings, which feed your load.
The automatic voltage regulator senses the output and adjusts the exciter to hold voltage steady as the load changes.
Product range
Send your model and serial number and our parts team confirms the correct part and price.
Power-generation alternators matched to engine output, voltage and frequency.
The parts that create and regulate the magnetic field.
For worn, noisy or damaged machines.
The smaller alternator that keeps the starting batteries charged.
Our services
Winding resistance and insulation tests, plus diode and AVR checks, on site or in the workshop.
Fit the correct AVR and set voltage and stability for your load.
Replace worn bearings and check alignment before noise turns into damage.
Rewinding where it is economical; where it is not, we recommend a matched replacement.
Alternators sized to engine output, voltage, frequency and load profile.
Prove output, voltage regulation and temperature under load after a repair.
Fault guide
What alternator faults look like, what usually causes them and what we do about it.
| Symptom | Likely causes | What we do |
|---|---|---|
| No output voltage | Lost residual magnetism, failed AVR, open-circuit exciter or failed diodes | Test the exciter, diodes and AVR, and restore the field if needed |
| Low voltage | AVR setting, a failed diode, or the engine running under speed | Check engine speed first, then the diodes and AVR |
| Unstable or hunting voltage | AVR stability setting, engine speed fluctuation or loose connections | Separate engine-speed faults from AVR faults, then adjust or replace |
| High voltage | A failed AVR or a lost sensing connection | Shut down to protect equipment, then replace the AVR and check sensing |
| Overheating | Blocked air vents, overload or unbalanced phase loads | Clean the machine and check load and phase balance |
| Noise or vibration | Worn bearings or misalignment | Replace bearings and check the coupling alignment |
| Low insulation resistance | Moisture, dust or ageing windings | Clean and dry the windings, or rewind if they have broken down |
Duty ratings
An alternator is rated for the way it will be used. Telling us the duty is as important as the kVA.
Maintenance advice
Getting the right part
Engine or generator model, serial number and the part you need.
Our parts team checks compatibility, price and stock.
Collect, arrange delivery, or have our technicians fit it.
FAQ
Yes, where a rewind is economical. Otherwise we recommend a matched replacement.
Common causes are AVR faults, failed diodes or engine speed issues. We diagnose on site or in the workshop.
Our Perkins-powered generator sets use Mecc Alte, Stamford (Newage) or Leroy-Somer alternators. For other makes, send us the rating plate details and we confirm what we can supply.
Usually lost residual magnetism, a failed AVR or failed diodes. We test the excitation system to find which before replacing anything.
Yes, once tests confirm the AVR is the fault. We fit the correct model and set it up for your alternator and load.
Yes. We supply the battery-charging alternators, belts and regulators fitted to the engine, as well as the main power-generation alternator.
Other categories

Generator engines and the components that keep them running — including Perkins engine parts.
Browse
Generator alternators and alternator components for replacement, repair and upgrades.
Browse
Oil, fuel and air filters plus complete service kits for scheduled maintenance.
Browse
Fuel system, injection, turbocharging, cooling and sensor components.
Browse
Controllers, transfer switches, AVRs and the electrical components behind reliable starting and control.
Browse
Genuine Perkins filters, kits and engine components.
BrowsePlan the next step
Our team will review the application and route your enquiry to the right solution.