Generators by application

Commercial generators

Reliable generator systems for offices, retail, hospitality, healthcare, schools and commercial facilities.

Commercial generators
10–3,000 kVA
Commercial range
Standby & prime
Duty ratings
Paralleling
Scalable capacity
Service
Planned maintenance plans

Overview

Keep trading, teaching and caring through every outage.

Offices, retail centres, hotels, schools and clinics depend on uninterrupted power for revenue, safety and customer experience. Downtime means lost sales, spoiled stock and disrupted services.

Powermec specifies commercial generator systems around building loads and critical circuits, then delivers the full installation — fuel systems, changeover, synchronisation and remote monitoring — backed by planned maintenance contracts.

Typical use cases

  • Offices
  • Hotels
  • Schools
  • Retail
  • Hospitals
  • Commercial property

Key benefits

What the right generator delivers.

Business continuity

Tills, IT, lifts, HVAC and cold rooms continue operating when the grid fails.

Protect revenue

Avoid lost trading hours, spoiled inventory and penalties on service-level agreements.

Compliance & safety

Emergency lighting, fire systems and medical equipment remain powered.

Scalable systems

Synchronised sets let capacity grow as the building or tenant mix changes.

System options

Typical configurations.

Every hour without power costs a commercial site revenue, stock and customer trust. Our commercial generator systems are specified around building loads, critical circuits and uptime requirements, then installed and maintained so trading, teaching and care continue through outages.

  1. 01

    Critical-circuit standby

    A generator dedicated to essential distribution boards: IT, security, lifts and refrigeration.

  2. 02

    Full-building standby

    Sized for the entire facility, with bulk fuel storage for extended outages.

  3. 03

    Multi-set synchronised plant

    Two or more generators in parallel for redundancy (N+1) and load sharing.

Choosing a generator

Key considerations.

Four questions decide the right set. Answer them with our team and the recommendation follows.

  1. 01

    Critical versus full-site backup

    Decide whether the generator carries the whole building or only critical circuits such as IT, lifts and cold rooms.

  2. 02

    Standby or prime duty

    Standby ratings cover grid outages; prime ratings suit sites that run on generator power for extended periods.

  3. 03

    Synchronisation and growth

    Paralleling capability lets you add capacity as the facility expands.

  4. 04

    Service continuity

    Scheduled maintenance and load testing keep the system ready when it is needed most.

Perkins engines

Perkins engines for commercial use.

Perkins engine series covering the 10kVA – 3,000kVA range. Not sure which fits? Send us your loads and we will recommend one.

Perkins 400 Series engine

Perkins 400

(9 – 20 kVA)

12-Month Manufacturer’s Warranty

  • 3 cylinders, inline
  • Natural aspiration and turbocharged
  • Mecc Alte, Newage Stamford or Leroy Somer alternators
ModelNetLengthWidthHeight
PCS9P396 kg1,1605701,100
PCS13P480 kg1,1605701,190
PCS20P565 kg1,3305701,250

Dimensions in mm

  • High performance
  • Compact size and low noise level, lower fuel consumption and oil use
  • Indirect injection combustion
  • 500-hour service intervals
  • Available on open and silent sets
Perkins 1103 Series engine

Perkins 1103

(30 – 60 kVA)

12-Month Manufacturer’s Warranty

  • 3 cylinders, inline
  • Natural aspiration and turbocharged
  • Mecc Alte, Newage Stamford or Leroy Somer alternators
ModelNetLengthWidthHeight
PCS30P800 kg1,5007001,400
PCS45P1,000 kg1,6007001,400
PCS60P1,020 kg1,6507001,500

Dimensions in mm

  • High performance
  • Compact size and low noise level, lower fuel consumption and oil use
  • Indirect injection combustion
  • 500-hour service intervals
  • Available on open and silent sets
Perkins 1104 Series engine

Perkins 1104

(65 – 100 kVA)

12-Month Manufacturer’s Warranty

  • 4 cylinders, inline, turbocharged
  • Mecc Alte, Newage Stamford or Leroy Somer alternators
  • Water cooled, engine speed 1500 rpm
ModelNetLengthWidthHeight
PCS80P1,088 kg1,8207201,500
PCS100P1,137 kg1,8627201,500

Dimensions in mm

  • High performance
  • Compact size and low noise level, lower fuel consumption and oil use
  • 500-hour service intervals
  • Direct injection combustion
  • Available on open and silent sets
Perkins 1106 Series engine

Perkins 1106

(100 – 150 kVA)

12-Month Manufacturer’s Warranty

  • 6 cylinders, inline, turbocharged
  • Mecc Alte, Newage Stamford or Leroy Somer alternators
  • Water cooled, engine speed 1500 rpm
ModelNetLengthWidthHeight
PCS100P1,226 kg1,5007311,500
PCS140P1,312 kg2,3007711,585
PCS150P1,354 kg2,3007711,585

Dimensions in mm

  • High performance
  • Compact size and low noise level
  • Lower fuel consumption and oil use
  • Fastram combustion and oil-spray-cooled pistons
  • Direct injection combustion

Perkins 1300

(200 – 250 kVA)

12-Month Manufacturer’s Warranty

  • 6 cylinders, inline, turbocharged A2A
  • Mecc Alte, Newage Stamford or Leroy Somer alternators
  • Water cooled, engine speed 1500 rpm
ModelNetLengthWidthHeight
PCS200P1,840 kg2,5508651,900
PCS225P1,925 kg2,5508651,900
PCS250P1,925 kg2,5508651,900

Dimensions in mm

  • High performance
  • Economic power: electronic engine management
  • Reliable power: valve and injector cooling system
  • Clean power: forced induction and electronic injection
Perkins 2200 Series engine

Perkins 2200

(300 – 400 kVA)

12-Month Manufacturer’s Warranty

  • 6 cylinders, inline, turbocharged A2A
  • Mecc Alte, Newage Stamford or Leroy Somer alternators
  • Water cooled, engine speed 1500 rpm
ModelNetLengthWidthHeight
PCS300P3,600 kg3,2001,1312,169
PCS350P3,600 kg2,3001,1312,169
PCS400P3,725 kg2,3001,1312,169

Dimensions in mm

  • High performance
  • Economic power: electronic fuel injection
  • Reliable power: high compression ratios
  • Clean, efficient power: exceptional power-to-weight ratio

Perkins 2500

(450 – 500 kVA)

12-Month Manufacturer’s Warranty

  • 6 cylinders, inline, turbocharged A2A
  • Mecc Alte, Newage Stamford or Leroy Somer alternators
  • Water cooled, engine speed 1500 rpm
  • High performance
  • Economic power: electronic fuel injection
  • Reliable power: high compression ratios
  • Clean, efficient power: exceptional power-to-weight ratio
Perkins 2800 Series engine

Perkins 2800

(600 – 650 kVA)

12-Month Manufacturer’s Warranty

  • 6 cylinders, inline, turbocharged A2A
  • Mecc Alte, Newage Stamford or Leroy Somer alternators
  • Water cooled, engine speed 1500 rpm
ModelNetLengthWidthHeight
PCS600P4,725 kg3,4101,5502,272
PCS650P4,835 kg3,4101,5502,272

Dimensions in mm

  • High performance
  • Economic power: electronic fuel injection
  • Reliable power: high compression ratios
  • Clean, efficient power: exceptional power-to-weight ratio
  • Direct injection combustion
Perkins 4006 Series engine

Perkins 4006

(730 – 800 kVA)

12-Month Manufacturer’s Warranty

  • 6 cylinders, inline, turbocharged A2A
  • Mecc Alte, Newage Stamford or Leroy Somer alternators
  • Water cooled, engine speed 1500 rpm
ModelNetLengthWidthHeight
PCS730P6,400 kg3,9901,7112,300
PCS800P6,400 kg3,9901,7112,300

Dimensions in mm

  • High performance
  • Economic power: 4-valve heads
  • Reliable power: piston jet cooling
  • Clean, efficient power: low gaseous emissions
Perkins 4008 Series engine

Perkins 4008

(910 – 1,000 kVA)

12-Month Manufacturer’s Warranty

  • 8 cylinders, inline, turbocharged A2A
  • Mecc Alte, Newage Stamford or Leroy Somer alternators
  • Water cooled, engine speed 1500 rpm
ModelNetLengthWidthHeight
PCS910P7,400 kg4,6502,0502,270
PCS1000P7,500 kg4,6502,0502,270

Dimensions in mm

  • High performance
  • Economic power: 4-valve heads
  • Reliable power: piston jet cooling
  • Clean, efficient power: low gaseous emissions
Perkins 4012 Series engine

Perkins 4012

(1,250 – 1,500 kVA)

12-Month Manufacturer’s Warranty

  • 12 cylinders, V-form, turbocharged A2A
  • Mecc Alte, Newage Stamford or Leroy Somer alternators
  • Water cooled, engine speed 1500 rpm
ModelNetLengthWidthHeight
PCS1250P8,900 kg4,7301,7802,450
PCS1500P10,000 kg4,9902,1902,510

Dimensions in mm

  • High performance
  • Economic power: 4-valve heads
  • Reliable power: piston jet cooling
  • Clean, efficient power: low gaseous emissions
Perkins 4016 Series engine

Perkins 4016

(1,850 – 2,250 kVA)

12-Month Manufacturer’s Warranty

  • 16 cylinders, V-form, turbocharged A2A
  • Mecc Alte, Newage Stamford or Leroy Somer alternators
  • Water cooled, engine speed 1500 rpm
ModelNetLengthWidthHeight
PCS1850P13,200 kg5,7102,7803,510
PCS2000P13,200 kg5,7102,7803,510
PCS2250P13,300 kg5,7102,7803,510

Dimensions in mm

  • High performance
  • Economic power: 4-valve heads
  • Reliable power: piston jet cooling
  • Clean, efficient power: low gaseous emissions

Turnkey delivery

What’s included in a Powermec installation.

  • Load survey and sizing report
  • Containerised or canopied sets
  • Bulk fuel tanks and day tanks
  • ATS and synchronising panels
  • Remote monitoring options
  • Planned maintenance contracts

FAQ

Common questions.

Should we back up the whole building?

It depends on your operations and budget. Many sites start with critical circuits and add capacity later through paralleling.

What is the difference between standby and prime?

Standby ratings cover grid outages for limited hours per year. Prime ratings suit sites that run on generator power for long periods.

Do you offer maintenance contracts?

Yes. We offer scheduled services, load-bank testing and emergency call-outs under a single agreement.

Plan the next step

Tell us what needs power.

Our team will review the application and route your enquiry to the right solution.